Online Catalog Fast Entry Order History Get Quote View Cart

Connector Wiring Instructions
Circular MS Connectors / 2 to 35 Pins
To 1750 Volts / to 23 Amps / Air Service to 125°C

 


Parts Nomenclature

 

Step 1. Slide the cable clamp, rubber bushing, back shell and nut (in that order) over cable, then strip each conductor .25'' as detailed.

 

 

Step 2. Insert each conductor in the corresponding contact solder cup (note that contacts are identified in a clockwise
pattern by alphabetical markings on insulator) then solder in place using a non acid core 60 - 40 tin lead solder.

 

 

Step 3. Slide nut over front shell, then thread back shell on to front shell and tighten. Slide rubber bushing into clamp, then thread the clamp on to back shell and tighten. Moderately tighten clamp screws to provide adequate strain relief to wire and contact solder joints.

 

Go to Circular MS Connectors -2 to 35 pins products listing