Connector Wiring Instructions Circular MS Connectors / 2 to 35 Pins To 1750 Volts / to 23 Amps / Air Service to 125°C
Parts Nomenclature
Step 1. Slide the cable clamp, rubber bushing, back shell and nut (in that
order) over cable, then strip each conductor .25'' as detailed.
Step 2. Insert each conductor in the corresponding contact solder cup (note
that contacts are identified in a clockwise
pattern by alphabetical markings on insulator) then solder in place using a
non acid core 60 - 40 tin lead solder.
Step 3. Slide nut over front shell, then thread back shell on to front shell and
tighten. Slide rubber bushing into clamp, then thread the clamp on to back shell
and tighten. Moderately tighten clamp screws to provide adequate strain relief
to wire and contact solder joints.