Online Catalog Fast Entry Order History Get Quote View Cart

Connector Wiring Instructions
Circular MS Connectors / 4 to 35 Pins
To 700 Volts / to 10 Amps / Air and Vacuum Service to 350°C

 


Parts Nomenclature
 

Step 1. Slide the cable clamp, back shell and nut (in that order) over cable, then strip each conductor .25'' as detailed.

 

 

Step 2. Remove retainer ring from front shell and disassemble by sliding insulators and contacts. Note that insulator consists of front and back pieces. Insert wires through the appropriate sides in back insulator before crimping contacts.

 

Step 3. Slide contacts on to wire and crimp in place.

 

 

Step 4. Insert crimped contacts into appropriate holes in front insulator. Note alignment slots on insulators.


 

Step 5. slide the front and back insulators together and insert them into the front shell. Secure them in place with the retainer ring.

 

Step 6. slide the nut over the front shell, then thread the back shell on to the front shell and tighten. Thread the clamp on to the back shell and tighten. Moderately tighten clamp screws to provide adequate strain relief to wire and contacts.
 

Go to Circular MS Connectors / 4 to 35 Pins.