Online Catalog Fast Entry Order History Get Quote View Cart

Connector Wiring Instructions
Coaxial / SHV-10

Step 1. Slide shrink tube and grip sleeve over cable jacket. Cut and strip cable jacket, braided shield and dielectric to dimensions shown. Do not nick conductor.

 

Step 2. Wet exposed conductor using a non acid core 60-40 tin lead solder, slide cable seal gasket and contact on conductor
then solder in place. Cable seal gasket must be under compression after soldering. Do not over heat cable dielectric, as swelling may prevent insertion of cable into shell. Flare braid as shown without fraying.

 

Step 3. Slide cable assembly into shell as far as it will go. At this stage the shell grip fingers should be under the flared braid as shown.

 

Step 4. Slide grip sleeve forward over braid to within .06" of shell body, crimp in place using Kings crimp tool number KTH-1000 and crimp die number KTH-2001. Place shrink tube over cable and shell, heating to 300ºF maximum. Finally,
insert interface seal over contact.