Online Catalog Fast Entry Order History Get Quote View Cart

Connector Wiring Instructions
Thermocouple MS Circular Connector. Air Service to 125°C.


Parts Nomenclature


Step 1. Slide the cable clamp, rubber bushing, back shell and nut (in that order) over cable, then strip each conductor .25 as detailed.

 

 

Step 2. Remove retainer ring from front shell and disassemble by sliding insulators and contacts. Note that the insulator consists of front and back pieces. Insert TC wires through the appropriate holes in back insulator before crimping contacts.
 
Step 3. Slide TC contacts on to corresponding TC wire and crimp in place. Note that TC contacts must be crimped to TC wires, never soldered.



Step 4. Insert crimped TC contacts into appropriate holes in front insulator. Note alignment slots on insulators.

 

Step 5. Slide the front and back insulators together and insert them into the front shell. Secure them in place with the retainer ring.

 

 

Step 6. Slide the nut over the front shell, then thread the back shell on to the front shell and tighten. Slide the rubber bushing inside the clamp. Thread the clamp on to the back shell and tighten. Moderately tighten clamp screws to provide adequate strain relief to wire and contacts.
 

Go to Thermocouple MS Circular Connector. Air Service to 125°C products listing